- Read head with guard locking without guard lock monitoring
- Locking force 650 N
- Adjustable adhesive force
- Up to category 4 according to EN ISO 13849-1
- Two safety screws M5x16 included
Euchner CEM-A-LE05H-S2-104606 CEM read heads
Stok kodu:
104606
Kategoriler: Harici değerlendirme ile transponder kodlu okuma kafaları, Sensörler
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Adjustable adhesive force
This version has an adhesive force also with the guard locking switched off. In this way it is intended, for example, to prevent the safety door opening due to vibration or similar. The adhesive force can be adjusted using a programming adapter to 70 N, 110 N or 150 N.
Important:To change the preset adhesive force, you will need a programming adapter.
Approach direction
Typical operating distance
Note assured switch-off distance sar = 20 mm for internal component failure. Safety outputs are reliably switched off.
Dimension drawing
Wiring diagram
Electrical connection ratings
Work area
Material | |
Read head | Plastic (PPS) |
Solenoid | Steel, nickel-plated |
Housing material | Die-cast aluminum |
Weight | |
Net | 0,3 kg |
Ambient temperature | -25 ... 50 °C |
Degree of protection | IP67 |
Mechanical life | |
In case of use as door stop, and 1 Joule impact energy | 1 x 106 |
Installation orientation | Any |
Switching frequency | |
Read head | See operating instructions for the related evaluation unit |
Solenoid | max.1 Hz |
Connection | |
X1, solenoid (yellow LED integrated in the plug) | Plug connector M8x1, 4-pin male (with snap-action / screw terminal) |
X3, read head | Plug connector M8x1, 3-pin male (with snap-action / screw terminal) |
Cable length | max.25 m |
Guard locking principle | Open-circuit current principle |
Locking force F | |
(Not monitored, in axial direction) at UCM?24V | 650 N |
Adhesive force | |
At UCM = 0V (default setting on delivery) | 110 N |
Programmable with adapter | 70, 110, 150 |
Operating voltage DC | |
UCM | 24 V DC -15% ... 10% |
UB | 24 V DC -15% ... 10% |
Current consumption | |
On UCM at 24V | 10 mA |
On UB at UCM?0V | 25 mA |
On UB at UCM?24V | 100 mA |
Power consumption | 2,8 W |
Solenoid duty cycle | 100 % |
Switching hysteresis | 0,7 mm |
Assured switch-off distance Sar | max.20 mm |
Assured operating distance Sao | min.2 mm |