- Safety switches with guard locking for process protection and integrated evaluation electronics
- Solenoid with locking force 600 N
- Adhesive-force adjustment in 3 levels
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4 / PL e according to EN ISO 13849-1 for door position monitoring
- With plug connector M12
- Unicode
- Door monitoring output
Euchner CEM-I2-AY-U-C40-SA-128103 CEM-AY-C40 safety switch with guard locking
Stok kodu:
128103
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
Guard locking type
Connector assignment
Electrical connection ratings
Work area
Reliability values according to EN ISO 13849-1
CEM?I2 | Guard locking actuated by energy ON and released by energy OFF. |
Plug connector (view of connection side) | Pin | Designation | Function |
---|---|---|---|
1 | IMP | Operating voltage of guard locking solenoid 24 V DC | |
2 | UB | Operating voltage, 24 V DC | |
3 | FO1A | Safety output, channel 1 | |
4 | FO1B | Safety output, channel 2 | |
5 | OI | Diagnostic output | |
6 | OT | Door monitoring output | |
7 | OL | Guard locking monitoring output | |
8 | 0 V UB | Operating voltage, 0 V |
Material | |
Read head | Plastic (PBT) |
Solenoid | Nickel-plated steel |
Housing material | Aluminum |
Weight | 0,64 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP65/IP67 |
Resilience to vibration | In acc. with EN 60947-5-3 |
Mechanical life | |
In case of use as door stop, and 1 Joule impact energy | 1 x 106 |
Installation orientation | Any |
Tightening torque | |
Fixing screws | 4 Nm |
Ready delay | 12 s |
Connection | Plug connector M12, 8-pin |
Locking force Fmax | |
In axial direction | 600 N |
Adhesive force | |
adjustable | 0, 30, 50 N |
Test pulses | max.0,8 ms |
Operating voltage | |
DC | 24 V -15% ... +15% |
Rated conditional short-circuit current | 100 A |
Current consumption | |
Guard locking inactive | 80 mA |
Guard locking active | 350 mA |
Fusing | |
External (operating voltage UB) | 1 A |
Rated insulation voltage Ui | max.30 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
EMC protection requirements | In acc. with EN 60947-5-3 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Switch-on time | |
Safety outputs | 700 ... 2500 ms |
Monitoring output OT | 700 ... 2500 ms |
Safety class | III |
Discrepancy time | max.10 ms |
Risk time according to EN 60947-5-3 | max.260 ms |
OT, OI, OL | |
Type of output | Semiconductor output, p-switching, short circuit-proof |
Switching current | |
Per monitoring output | max.50 mA |
Output voltage | 0,8 x UB ... UB V DC |
FO1A/FO1B | |
Type of output | Semiconductor outputs, p-switching, short circuit-proof |
Switching frequency, electrical | 0,5 Hz |
Switching current | |
Per output | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB - 1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Utilization category according to EN 60947-5-2 | |
DC-13 | DC-13 24V 150mA |
Off-state current Ir | max.0,25 mA |
Assured switch-off distance Sar | 18 mm |
Center offset | -5 ... +5 mm |
Monitoring of the position of the safety guard | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.5 x 10-9 |
Mission time | 20 y |