- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6,500 N
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With two plug connectors M12
- Unicode
- Escape release, 105 mm long
- Indication of the door position by LED
- Approach direction A (delivery state)
Euchner CET3-AP-CRA-AH-50F-SI-C2312-157408 CET-AP safety switch with guard locking
Stok kodu:
157408
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Safety SwitchThe device may be operated only in conjunction with the actuator CET-A-....
Important: The actuator must be ordered separately.
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
Solenoid operating voltage
LED function display
Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
Electrical connection ratings
Work area
Other
Reliability values according to EN ISO 13849-1
- DC 24 V +10% -15%
CET3 | Guard locking by spring force. The door position is also monitored. LED 2 illuminates as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). LED 2 also remains on when guard locking is active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | Voltage at the solenoid |
LED 2 gn | Door position |
- Category 4/PL e according to EN ISO 13849-1
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 1 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (operating voltage UB) | 0,25 ... 8 A |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
Power consumption | |
Solenoid | max.12 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Low U(OA) / U(OB) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Repeat accuracy R | 10 % |
C number | |
C2312 | Extended escape release |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
Category | |
Head downward or horizontal | 4 |
Head upward | 3 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Mission time | 20 y |