- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 6500 N
- Up to 20 switches in series
- Short circuit monitoring
- 2 safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With 2 plug connectors M12
- Unicode
- Door monitoring output
- Indication of the door position by LED
- Teach-in input
- Wire front release (bowden), 3 m
- Approach direction A (default setting on delivery)
Euchner CET4-AR-CRA-AH-50X-SG-C2290-128193 CET-AR safety switch with guard locking
Stok kodu:
128193
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Safety switchThe device may be operated only in conjunction with the actuator CET-A-....
Important: The actuator must be ordered separately.
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
Solenoid operating voltage
LED function display
Additional connections
Category according to EN ISO 13849-1Due to two redundantly designed semiconductor outputs (safety outputs) with internal monitoring suitable for:
Electrical connection ratings
Work area
Other
Reliability values according to EN ISO 13849-1
- DC 24 V +10% -15%
CET4 | Open-circuit current principle guard locking by solenoid force. Activation of the guard locking by applying voltage to the guard locking solenoid. The door position is also monitored. The door monitoring output OUT D is set to HIGH as soon as the actuator is above the extended plunger (state: door closed, guard locking not active). The output OUT D remains set also with guard locking active. |
LED State | Status LED |
LED DIA | Diagnostic LED |
LED 1 rd | freely configurable |
LED 2 gn | illuminates when door is closed |
OUT | Monitoring output (semiconductor) |
OUT D | Door monitoring output |
RST | Reset input |
J | Teach-in input |
- Category 4/PL e according to EN ISO 13849-1
Housing material | |
Slide | Stainless steel |
Safety switch housing | Die-cast aluminum |
Weight | |
Net | 1 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP67 |
Resilience to vibration | In acc. with EN IEC 60947-5-2 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Degree of freedom | |
Z | ±4 mm |
Y | ±5 mm |
X | ±5 mm |
Ready delay | 10 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5 and 8-pin |
Approach speed | 20 m/min |
Guard locking principle | Open-circuit current principle |
Locking force Fmax | 6500 N |
Locking force FZh | 5000 N |
Operating voltage DC | |
UB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
LED | 24 V DC -15% ... 10% |
Current consumption | |
IB | 80 mA |
ICM | 480 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 200mA |
Solenoid operating voltage DC | |
UCM | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage UCM) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Power consumption | |
Solenoid | max.14 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | 30V DC, 2A |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs OA/OB | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output OA / OB | 1 ... 200 mA |
Output voltage | |
Low U(OA) / U(OB) | 0 ... 1 V DC |
High U(OA) / U(OB) | UB-1,5V ... UB V DC |
Off-state current Ir | max.0,25 mA |
Risk time according to EN 60947-5-3 | |
Single device | max.400 ms |
Delay per device | 5 ms |
Switch-on time | 400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms |
Monitoring output OUT | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT | 1 ... 50 mA |
Output voltage | |
OUT | 0,8xUB ... UB V DC |
Switching delay from state change | max.400 ms |
Monitoring output OUT D | |
Type of output | p-switching, short circuit-proof |
Switching current | |
OUT D | 1 ... 50 mA |
Output voltage | |
OUT D | 0,8xUB ... UB V DC |
Switching delay from state change | max.700 ms |
Teach-in input | |
Input voltage | |
Low | 0 ... 1 V DC |
High | 15 ... 27,6 V DC |
Repeat accuracy R | 10 % |
C number | |
C2290 | With wire front release (bowden) mounted |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Monitoring of guard locking and the safety guard position | |
Category | |
Head downward or horizontal | 4 |
Head upward | 3 |
Performance Level | PL e |
PFHD | |
Head upward | 4.29 x 10-8 |
Head downward or horizontal | 3.1 x 10-9 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Mission time | 20 y |
Classification according to EN IEC 60947-5-3 |