- Serial interface RS232
- Active face can be adjusted to 5 different positions
- Standard housing according to EN 50041
- Connection terminals
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Serial interfaceThe individual commands for reading and writing the data carrier are in accordance with the common 3964R protocol and are described in the EUCHNER CIS3 system manual (order no. 071 652). For data carrier programming away from the system, a convenient WINDOWS®-compatible PC software application is available (Software Transponder Coding, see page 41).
Standard housingThe size of the robust housing in degree of protection IP65 is compliant with the standard EN 50041. The division into 3 assemblies permits easy mounting and straightforward replacement.
Mounting instructionsOn mounting the read/write head and data carrier, it is to be ensured the crossing direction as per the direction of the arrow on the active face of the read/write head is observed.
Attention:On the usage of a screened cable the connection cable for the serial interface is allowed to be max. 5 m long.
Electrical connection ratings
Interface, bus
In combination with Data carrier CIS3P16D08KH16YSNOU, CIS3P16D08KH16YSNOPOperating distance
In combination with Data carrier CIS3P35X16SH16YHNOP, CIS3P35X16SH16YHNOU, CIS3P35X16SH16YVNOP, CIS3P35X16SH16YVNOUOperating distance
Housing material | Plastic |
Ambient temperature | 0 ... 55 °C |
Degree of protection | IP65 |
Connection | Screw terminal |
Cable length | max.5 m RS232 |
Operating voltage DC | 20 ... 24 ... 28 V DC |
Current consumption | max.140 mA |
LED indicator | |
Green | Operational |
Yellow | Data carrier in operating distance |
Data interface | RS232 |
Data protocol | 3964R via RS232 8 data bits, even parity |
Data rate | 9,6 kbit/s |
Read distance | 0 ... 5 ... 14 mm |
Center offset | |
At 25°C, read distance s=5mm, in X direction | -10 ... 10 mm |
At 25°C, read distance s=5mm, in Y direction | -6 ... 6 mm |
Write distance | |
At 25°C | 0 ... 5 ... 9 mm |
Read distance | |
At 25°C | 0 ... 7 ... 18 mm |
Center offset | |
At 25°C, read distance s=5mm, in Y direction | -8 ... 8 mm |
At 25°C, read distance s=5mm, in X direction | -10 ... 10 mm |
Write distance | |
At 25°C | 0 ... 5 ... 10 mm |