- Safety switch with guard locking and integrated evaluation electronics
- Direct connection to decentralized peripheral systems (e.g. ET200pro)
- Short circuit monitoring
- Two safety outputs (semiconductor outputs)
- Up to category 4/PL e according to EN ISO 13849-1
- With two plug connectors M12
- Unicode
- With escape release
- Approach directions A, B and C (delivery state)
Euchner CTP-L1-AP-U-HA-AE-SII-127640 CTP-AP safety switch with guard locking
Stok kodu:
127640
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Each actuator is unique. The switch detects only taught-in actuators. Additional actuators can be taught in. Only the last actuator taught in is detected.
Guard locking type
Escape release
This is used for manual release of guard locking from the danger zone without tools.
Connector assignment
Electrical connection ratings
Work area
Other
Reliability values according to EN ISO 13849-1
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
Plug connector (view of connection side) | Pin | Designation | Function | Conductor coloring of connecting cable |
---|---|---|---|---|
X 1.1 | UB | Operating voltage of AP electronics 24 V DC | BN | |
X 1.2 | FO1A | Safety output, channel 1 | WH | |
X 1.3 | 0 V UB | Operating voltage of AP electronics 0 V | BU | |
X 1.4 | FO1B | Safety output, channel 2 | BK | |
X 1.5 | - | Not used | GY | |
X 2.1 | - | Not used | BN | |
X 2.2 | - | Not used | WH | |
X 2.3 | IMM | Control input of guard locking solenoid, 0 V | BU | |
X 2.4 | IMP | Guard locking solenoid control input 24 V DC | BK | |
X 2.5 | - | Not used | GY |
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 2 plug connectors M12, 5-pin + pin 5 not used |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 2 A |
Rated insulation voltage Ui | max.50 V |
Rated impulse withstand voltage Uimp | max.0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Switch-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Repeat accuracy R | 10 % |
Additional feature | Escape release actuated by pushing |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |