- Safety switch with guard locking and integrated evaluation electronics
- Locking force up to 3,900 N
- Category 4/PL e according to EN ISO 13849-1
- Unicode
- Approach directions A, B and C (delivery state)
Euchner CTP-L1-AS1B-U-HA-AZ-SJ-124987 CTP-AS safety switch with guard locking
Stok kodu:
124987
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal
Can be adjusted in 90° steps
Guard locking type
Control of the guard locking solenoid
The guard locking solenoid can be controlled via AS-Interface bus bit D0 or via the auxiliary power.
AS-Interface inputs
Evaluation is performed via a safety monitor.
AS-Interface outputs
LED function display
Electrical connection ratings
Work area
Other
Reliability values according to EN ISO 13849-1
CTP?L1 | Guard locking actuated by spring force applied and power-ON released (closed-circuit current principle) |
D0, D1 | Door monitoring |
D2, D3 | Guard lock monitoring |
D0 | Guard locking |
- The ASI LED indicates the state of the ASi bus.
- The STATE LED indicates the state of the switch.
- The LOCK/DIA LED indicates if the door is locked and whether a fault has been detected in the switch.
Housing material | |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | -20 ... +55 °C |
Degree of protection | IP67 / IP69 / IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 4-pin |
Approach speed | 20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
ASi voltage | 30 V 26,5 ... 31,6 V |
ASi operating current | 50 mA |
ASi auxiliary voltage | |
IEC 60742, PELV | 24 V -15% ... +10% |
ASi auxiliary current | 400 mA |
ASi slave type | |
According to ASI specification 3.0 | EA code: 7 |
ID code: B | |
ASi data in | |
According to As-i Safety at Work | D1 |
D2 | |
D3 | |
D0 | |
ASi data out | |
Guard locking solenoid | D0 |
Safety class | |
EN IEC 61140 | III |
Repeat accuracy R | 10 % |
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Performance Level | PL e |
Category | 4 |
PFHD | 4.3 x 10 -9 |
Mission time | 20 y |