- Plunger spacing 12 or 16 mm
- Horizontal housing
- Degree of protection IP67 according to IEC 60529
- LED function display optional
Euchner GLBF04R12-502-MC2050 Multiple limit switch, horizontal GLBF
Stok kodu:
96788
Kategoriler: Konum anahtarları ve çoklu limit anahtarları, Sensörler
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Switching elements
On the usage of safety switching elements, the dog distance must be maintained to achieve the positively driven travel. The dogs must be positively mounted according to EN 1088, i.e. riveted, welded or secured in some other way against becoming loose.
LED function display (optional)Function displays are available for the following voltage ranges (see accessories)
Dimension drawing
ES 502 E
ES 508
ES 514
Dimension drawingES 502 EES 508ES 514
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Other
ES 502 E | Snap-action switching contact 1 NC + 1 NO |
ES 508 | Slow-action switching contact 1 NC |
ES 514 | Snap-action switching contact 1 NC + 1 NO |
LE060 | 12 ... 60 V AC/DC |
LE110 | 110 V AC ±15% |
LE220 | 220 V AC ±15% |
Contact bounce time | < 3ms |
Contact closing time | < 4ms |
Design | Horizontal |
Housing material | Sand-cast aluminum, anodized |
Weight | |
Net | 1,9 kg |
Ambient temperature | -5 ... 80 °C |
Degree of protection | IP67 |
Mechanical life | 30 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Snap-action switching contact |
Plunger spacing | 12 mm |
Installation orientation | Any |
Number of switching elements | 4 |
Number of NC contacts | 4 |
Number of NO contacts | 4 |
Connection | 3 x M25 x 1.5 |
Approach speed | 0,01 ... 80 m/min |
Actuating element | Roller plunger |
Roller diameter | 8 mm |
Actuating force | min.20 N |
Operating point accuracy | ± 0.01 |
Thermal rated current Ith | 8 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 6A 230V |
DC-13 | 6A 24V |
AC-12 | 8 A, 250 V |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 8A gG |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching current | |
Min. at DC 12V | min.10 mA |
Connection cross-section | 0,34 ... 1,5 mm? |
C number | |
C2050 |