Specification
Profinet connection
Connection via push-pull plugs according to IEC 61076-3-117
Profinet RT switch
Point-to-point topology network structure due to integrated RT switch.
Dimension drawing
MGB: The MGB-System in use
MGB: MGB Impact test
MGB: Mounting left door, with escape release
Mounting left door, without escape release
Mounting right door, without escape release
MGB: Deactivating guard lock monitor
MGB: Activating guard lock monitor
MGB: Activating release monitoring
MGB: Change color-lens push button
Dimension drawing
Technical dataApprovals
Mechanical values and environment
Electrical connection ratings
Interface, bus
Controls and indicators
Other
Reliability values according to EN ISO 13849-1
Housing material | Reinforced plastic, die-cast zinc nickel-plated, stainless steel |
Weight | |
Net | 1,8 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... 55 °C |
Degree of protection | IP54 |
Resilience to vibration | In accordance with EN 60947-5-3 |
Installation orientation | Any |
Reaction time | |
Operating mode selector switch | max.220 ms Switch-off time |
Switching frequency | 0,25 Hz |
Connection | Push-pull power |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
Push-pull power | |
According to IEC 61076-3-117 variant 14, screened, Profinet I/O cable, at least cat. 5e | Push-pull RJ45 |
Current consumption | max.500 mA |
Rated insulation voltage Ui | 75 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Maximum feed-in current in the connection block | |
X1, X2 | max.4000 mA |
EMC protection requirements | In accordance with EN 61000-4 and EN 61326-3-1 |
Degree of contamination (external, according to EN 60947-1) | 3 |
Connecting cable | |
Ethernet | Profinet I/O cable, at least cat. 5e |
Safety class | III |
Power supply X1 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Fusing | |
external | min.1 A Slow blow |
Power supply X2 | |
Operating voltage DC | |
L1 | 24 V DC -15% ... 10% |
Auxiliary voltage DC | |
L2 | 24 V DC -15% ... +10% |
Data interface | |
Data protocol | |
Bus protocol | Profinet (IEC 61158 type 10) |
Safety protocol | Profisafe (IEC 61784-3-3) |
Belegungsschema | B2 |
Position 11 | |
Ausfuhrung | Cover for indicators |
Einlegeschild | |
Extras | |
Farbe | Red |
Schaltelement | |
Position 12 | |
Ausfuhrung | Illuminated push buttons |
Einlegeschild | |
Extras | |
Farbe | white |
Schaltelement | 1NO |
Position 13 | |
Ausfuhrung | Operating mode selector switch |
Einlegeschild | Entsichert / Unsecured ; Sonderfunktion / Special function ; Gesichert Zentral / Secured Central |
Extras | |
Farbe | |
Schaltelement | Code 2 of 3 |
Product version number | V3.23.3 |
Slide-in label | |
Anlage Gesichert | |
Quittieren | |
Line Secured | |
Line Reset |
Selector switch evaluation | |
Category | 4 |
Performance Level | PL e |
PFHD | 4.1 x 10-8 |
Performance Level | PL e |
Category | 4 |
Safety Integrity Level | SIL 3 (EN 62061:2005) |
Diagnostic Coverage (DC) | 99 |
Mission time | 20 |