- Version C according to EN 50041 NZ.RS (steel roller o 12 mm)
Euchner NZ2RS-538SEM4AS1 Electromechanical safety switches with AS – Interface
Stok kodu:
95046
Kategoriler: AS ile güvenlik mühendisliği - Arayüz, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Switching directionRight, left or both sides.
AS-Interface inputs
Evaluation is performed via a safety monitor.
AS-Interface outputs
LED function display
Electrical connection ratings
Reliability values according to EN ISO 13849-1
D0, D1 | Positively driven NC contact 1 |
D2, D3 | Positively driven NC contact 2 |
D1 | Red LED |
D2 | Green LED |
- The Power LED indicates the operating voltage on the bus.
- The Fault LED indicates if a fault has been detected on the AS-Interface bus.
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Housing material | Anodized die-cast alloy |
Weight | |
Net | 0,3 kg |
Ambient temperature | -25 ... 70 °C |
Degree of protection | IP67 |
Mechanical life | 30 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | |
According to ASI Safety at work | 2 D0, D1, D2, D3 |
Connection | |
1 x | Plug connector M12 |
Approach speed | |
max. | 0,1 ... 20 m/min |
Actuating element | |
Plain bearing metal | Roller plunger |
Actuating force | min.30 N |
ASi voltage | 30 V 22,5 ... 31,6 V |
ASi operating current | max.45 mA |
ASi slave type | |
According to ASI specification 2.1 | ID code B |
EA code 7 | |
ASi data in | |
According to ASI Safety at work | D0, D1 / D2, D3 |
ASi data out | |
LED red | D1 |
LED green | D2 |
ASi LED | |
LED green | Power |
LED red | Fault |
B10D | 20 x 106 |