- Actuating heads made of metal
- Simultaneous monitoring of two safety doors
- Auxiliary release on the front
- Mechanical key release
- With door monitoring contact
Euchner STA-TW-3A-2131AC024M-S1 STA metal switch with metal head
Stok kodu:
105888
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Solenoid operating voltage
Switching element
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. To protect against tampering, the auxiliary release is sealed with sealing lacquer.
Mechanical key releaseAdditional lock on the switch head. Function as for auxiliary release. The mechanical key release setting is indicated in the window. Two keys are included.
Electrical connection ratings
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-S-GT-SNMechanical values and environment
- AC/DC 24 V +10%, -15%
STA3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
2131 | Slow-action switching contact 2 NC + 1 NO + 1 NC (door monitoring contact) |
Housing material | Alloy - die-cast |
Weight | |
Net | 0,6 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position NC contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 |
Number of guard lock monitoring NO contacts | 1 |
Connection | |
3 x | M20 x 1.5 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 2500 N |
Locking force FZh | 2000 N |
Retention force | 20 N |
Extraction force | 30 N |
Actuating force | 35 N |
Insertion depth | min.24,5 mm |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 230V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 250 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
B10D | 4,5 x 106 |
Overtravel | 5 mm |