- Auxiliary release on the front
- Escape release from the rear
- With door monitoring contact
- Increased horizontal overtravel
Euchner TP3-4141A024MC1743 TP proven plastic switch
Stok kodu:
86165
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Increased overtravel for horizontal approach direction
Solenoid operating voltage
Switching element
Escape releaseThis is used for manual release of guard locking from within the danger area without tools. With identification of On/Off position.
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
- AC/DC 24 V +10%, -15%
TP3 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the guard locking solenoid. |
4141 | Slow-action switching contact 2 NC + 2 NC (door monitoring contacts) |
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | 4 |
Connection | |
3 x | M20 x 1.5 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 1300 N |
Locking force FZh | 1000 N |
Retention force | 10 N |
Extraction force | 20 N |
Actuating force | 10 N |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 50V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 2,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
Connection cross-section | 0,34 ... 1,5 mm? |
C number | |
C1743 | Escape release short |
Monitoring of guard locking and the safety guard position | |
B10D | 3 x 106 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Overtravel A B C D E | 2 mm |
Overtravel K L M N | 1,5 mm |
Overtravel A B C D E | 7 mm |