- Auxiliary release on the front
- Increased horizontal overtravel
- Optional without guard lock monitoring
Euchner TP4-4141A024SEM4AS1 TP proven plastic switch
Stok kodu:
88257
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Guard locking types
Control of the guard locking solenoidThe guard locking solenoid is controlled by the control system via AS-Interface bus bit D0. In addition the 24V connection can be switched safely.
AS-Interface inputs, version AS1
AS-Interface inputs, version AS1
Evaluation is performed via a safety monitor.
AS-Interface outputs
LED function display
Electrical connection ratings
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-P-GTMechanical values and environment
In combination with Actuator BETAETIGER-P-GNTMechanical values and environment
TP3 | Closed-circuit current principle, guard locking by spring force. Release by control of AS-i output 0. |
TP4 | Open-circuit current principle, guard locking by control of AS-i output 0. Release by spring force. |
D0, D1 | Door monitoring contact SK |
D2, D3 | Solenoid monitoring contact UK |
D0, D1 | Door monitoring contact SK 1 |
D2, D3 | Door monitoring contact SK 2 |
D0 | Guard locking solenoid |
D1 | Red LED |
D2 | Green LED |
- The Power LED indicates the operating voltage on the bus.
- The Fault LED indicates if a fault has been detected on the AS-Interface bus.
- The green and the red LEDs can be controlled as required by the control system via the bus using bits D1 and D2.
Housing material | Reinforced thermoplastic |
Weight | |
Net | 0,5 kg |
Ambient temperature | -20 ... 55 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position positively driven contacts | |
According to As-i Safety at Work | 1 D0,D1 |
Number of guard lock monitoring positively driven contacts | |
According to As-i Safety at Work | 1 D2,D3 |
Connection | |
1 x | Plug connector M12 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Open-circuit current principle |
Retention force | 10 N |
Extraction force | 20 N |
Actuating force | 10 N |
ASi voltage | 30 V 22,5 ... 31,6 V |
ASi operating current | max.45 mA |
ASi auxiliary voltage | |
IEC 60742, PELV | 24 V -15% ... +10% |
ASi auxiliary current | 300 mA |
Solenoid duty cycle | 100 % |
ASi slave type | |
According to ASI specification 2.1 | ID code: B |
EA code: 7 | |
ASi data in | |
According to ASI safety at work | D0,D1,D2,D3 |
ASi data out | |
LED red | D1 |
LED green | D2 |
Guard locking solenoid | D0 |
ASi LED | |
LED green | Power |
LED red | Fault |
B10D | 3 x 106 |
Overtravel | |
Horizontal | 2 mm |
Vertical | 1,5 mm |
Insertion depth | |
Horizontal | 28 mm |
Vertical | 29,5 mm |
Overtravel | |
Horizontal | 7 mm |
Insertion depth | |
Horizontal | 28 mm |