- Auxiliary release on the front
- With door monitoring contact
- Separate plug connector for solenoid monitoring and door monitoring with solenoid operating voltage
- For direct connection to PROFIsafe inputs/outputs
Euchner TX1B-A024MC2129 TX metal switch
Stok kodu:
97623
Kategoriler: Emniyet Anahtarları, Güvenlik anahtarları ve araçları
Açıklama
Ek bilgi
Brand |
---|
GET A PRICE
To receive a proposal, please send your application to info@avat-industrial.com and specify the required positions and company details.
Specification
Approach direction
Horizontal and vertical
Can be adjusted in 90° steps
Solenoid operating voltage
Switching element
Auxiliary releaseIs used for releasing the guard locking with the aid of a tool. The auxiliary release must be sealed to prevent tampering (for example with sealing lacquer).
Electrical connection ratings
Other
Reliability values according to EN ISO 13849-1
In combination with Actuator BETAETIGER-X-GQMechanical values and environment
In combination with Actuator BETAETIGER-X-GNQMechanical values and environment
- AC/DC 24 V +10%, -15%
TX1 | Closed-circuit current principle, guard locking by spring force. Release by applying voltage to the solenoid. |
ETX B | Slow-action switching contact 2 NC / 1 NO + 1 NC (door monitoring contact) |
Housing material | Die-cast alloy, cathodically dipped |
Weight | |
Net | 0,8 kg |
Ambient temperature | -20 ... 80 °C |
Degree of protection | IP67 |
Mechanical life | 1 x 106 |
Contact material | Silver alloy, gold flashed |
Switching principle | Slow-action switching contact |
Installation orientation | Any |
Number of door position NC contacts | 1 |
Number of guard lock monitoring positively driven contacts | 2 Switches green LED |
Number of guard lock monitoring NO contacts | 1 Switches red LED |
Connection | |
2 x | Plug connector M12 |
Approach speed | |
max. | 20 m/min |
Actuation frequency | 1200 1/h |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 1700 N |
Locking force FZh | 1300 N |
Retention force | 50 N |
Extraction force | 35 N |
Actuating force | 35 N |
Insertion depth | min.32 mm |
Thermal rated current Ith | 4 A |
Utilization category according to EN 60947-5-1 | |
AC-15 | 4A 60V |
DC-13 | 4A 24V |
Solenoid operating voltage | |
AC/DC | 24 V -15% ... +10% |
Short circuit protection according to IEC 60269-1 | |
(Fuse) | 4A gG |
Rated insulation voltage Ui | 63 V |
Rated impulse withstand voltage Uimp | 1,5 kV |
Switching voltage | |
Min. at 10mA | 12 V |
Switching current | |
Min. at 24V | 1 mA |
Power consumption | 8 W |
Solenoid duty cycle | 100 % |
LED indicator | Operating voltage corresponds to the solenoid voltage |
C number | |
C2129 |
Control of the guard locking | |
Category | Depending on external control of guard locking |
Performance Level | Depending on external control of guard locking |
PFHD | Depending on external control of guard locking |
Monitoring of guard locking and the safety guard position | |
B10D | 6 x 106 |
Overtravel | 1 mm |
Overtravel | 8 mm |